63P3F11
7-28
1
2
3
4
5
6
7
8
9
NOTE:
Hold the power trim and tilt unit with one
hand, and pull the upper mount shaft out at a
downward angle with the other.
6. Remove the collars.
Checking the hydraulic pressure
1. Remove the reservoir cap, and then
check the fluid level in the reservoir.
NOTE:
If the fluid is at the correct level, the fluid
should overflow out of the filler hole when the
reservoir cap is removed.
2. If necessary, add sufficient fluid of the
recommended type until it overflows out
of the filler hole.
3. Install the reservoir cap, and then tighten
it to the specified torque.
4. Fully extend the trim and tilt rams.
5. Remove the circlip
1
, then the manual
valve
2
.
6. Install the up relief fitting
3
and hydraulic
pressure gauge
4
.
NOTE:
Quickly install the special service tools before
any fluid flows out of the hole.
S60X7120
S60X7340
Recommended power trim and tilt
fluid:
ATF Dexron
II
Reservoir cap:
0.7 N·m (0.07 kgf·m, 0.5 ft·lb)
Up relief fitting
3
: 90890-06773
Hydraulic pressure gauge
4
:
90890-06776
Power trim and tilt unit