[No Assign]
No function will be assigned. This is the default value. Select this if you want to clear the function
assigned to a GPI IN port. The [Device], [Parameter], [Min], [Max], and [Trigger Type] fields are
unavailable.
[Scene Recall]
The specified scene will be recalled. Use [Device] to select the amplifier that will be controlled. If you
select “ALL,” all amplifiers connected to that device will be selected.
Use [Parameter] to specify the scene number that you want to recall.[Min] and [Max] are unavailable.
Use [Trigger Type] to specify how the input voltage from GPI IN will be applied to the parameter.
When is selected
The scene specified by [Parameter] will be recalled when the GPI IN input voltage changes from
below the center voltage to above it.
When is selected
The scene specified by [Parameter] will be recalled when the GPI IN input voltage changes from
above the center voltage to below it.
When is selected
Same as .
When is selected
Same as .
GPI IN input voltage
max
GPI IN input voltage
min
Center
voltage
Triggering occurs
GPI IN input voltage
max
GPI IN input voltage
min
Center
voltage
Triggering occurs