Yamaha SRCX Manuale Utente Pagina 19

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 18
13
CHAPTER2 DeviceNet Unit
2-5 Controller system settings (Slave station)
The MAC ID and the communication speed must be set so that the controller can be
correctly identified as a slave station on the DeviceNet system.
The MAC ID settings and communication speed settings are made with DIP switches on
the board.
These settings are enabled after the controller is restarted.
2-5-1 Validating the DeviceNet unit
Before the DeviceNet unit can be used, it must first be set as follows, to allow it to be
identified by the controller.
1) Press
F3
(SYS) on the initial screen.
2) Press
F4
(next) to switch the function
display and then press
F2
(OPT).
3) Press
F1
(DEV).
4) The current DeviceNet unit identity sta-
tus appears on the display.
Now, using the number key pad, enter a 1
to make the DeviceNet unit identifiable
from the controller or enter a 0 to prevent
it being identified from the controller, and
then press the
key.
5) When entry is finished, the screen returns
to 4).
[MENU]
select menu
1EDIT2OPRT3SYS 4MON
[SYS]
select menu
1SAFE2OPT 3UTL 4next
[SYS-OPT]
select menu
1DEV 2NODE3SPD 4next
[SYS-OPT-DEV]
DeviceNet=
0
0:invalid 1:valid
[SYS-OPT-DEV]
DeviceNet=
1
0:invalid 1:valid
Vedere la pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 81 82

Commenti su questo manuale

Nessun commento